Skip to content

Stormwater Detention in Manila: New Projects and the 72,000 m³ Proposal

On October 6, 2026, Manila took a concrete step toward stormwater detention: the Metropolitan Manila Development Authority (MMDA) and the city government signed an agreement to develop three rainwater impounding facilities. At the same time, officials continued discussing underground storage near the University of Santo Tomas (UST), where flooding along España Boulevard has persisted for decades.

One figure has attracted particular attention: 72,000 cubic meters (m³) of potential rainwater storage beneath the UST Open Field. However, that capacity belongs to an earlier proposal, not an approved or operating project. For this reason, understanding the difference is essential. Manila’s plans show why crowded cities are considering underground stormwater detention, but their eventual effectiveness will depend on detailed hydraulic design, drainage connections, construction and maintenance.

Manila’s 2026 Stormwater Detention Plans: What Has Actually Been Agreed?

According to The Philippine Star’s October 7 report, the MMDA and Manila agreed to pursue three rainwater impounding facilities (RIFs). Specifically, these stormwater detention facilities are intended to hold excess runoff temporarily and ease pressure on existing drains during heavy rainfall. The sites were identified following feasibility work by Haskoning, and the government has set June 30, 2027 as the target completion date.

  • Rajah Sulayman Park: A facility designed to provide underground or subsurface rainwater storage while allowing the public space above to remain part of the urban landscape.
  • Remedios Circle: A combined intervention involving rainwater storage, drainage improvements and nature-based solutions.
  • ASEAN Garden: A planned facility at the Cultural Center of the Philippines complex to intercept runoff from the Vito Cruz catchment through drainage along P. Ocampo Street.

Importantly, an agreement and a target date do not mean these facilities have already been built. Furthermore, the publicly reported information does not establish a storage capacity for each of the three sites. Their performance will therefore need to be assessed against approved engineering plans rather than assumed from the project announcement.

The UST Campus: 11,000 m³ Existing, 72,000 m³ Proposed

A separate story concerns the University of Santo Tomas and the heavily trafficked España Boulevard. As reported by The Varsitarian on October 9, the Department of Public Works and Highways (DPWH) presented a new underground detention basin proposal to university officials on October 6. At the time of reporting, the university was still reviewing that proposal.

UST already has an underground stormwater detention system beneath much of its campus road network. Work began in 2018, with a first phase completed in 2020 and further improvements in 2024; its reported storage capacity is approximately 11,000 m³. By contrast, the proposed 72,000 m³ catchment basin beneath the UST Open Field was revived in 2025 and remains uncommitted. The field has national cultural treasure status, which adds heritage protection considerations to any excavation proposal. In short, these figures describe different facilities at different stages; they must not be added together as if they represented available storage.

Meanwhile, DPWH has been improving street-level drainage. Officials reported widening four España Boulevard drainage inlets from 0.5 meters to 1.5 meters, with further inlet works planned. Nevertheless, larger inlets cannot remove a downstream bottleneck by themselves. For example, if the receiving pipe, river or pumping station is already at capacity, additional inflow may simply back up. That is precisely where detention storage can provide a temporary buffer.

How Does Underground Stormwater Detention Work?

Stormwater detention is the temporary storage of rainwater runoff followed by a controlled discharge. Instead of sending the entire storm peak into a drainage network at once, a detention basin, buried vault or modular tank receives excess runoff and releases it through a designed outlet. Consequently, the downstream peak flow can be lower, even though much of the stored water eventually enters the same drainage system.

In hydraulic terms, storage rises when incoming flow exceeds outgoing flow and falls when discharge becomes greater than inflow. Engineers evaluate that changing balance over the design storm, including the water already present when a new storm starts. Therefore, a tank’s nominal capacity alone does not establish flood protection. Instead, inlet capacity, outlet control, overflow routing and the time required to empty matter just as much.

For illustration, a 10,000 m² catchment receiving 50 mm of rainfall would collect 500 m³ before runoff losses are considered. With an illustrative runoff coefficient of 0.8, approximately 400 m³ could become direct runoff. However, 400 m³ is not automatically the required stormwater detention volume: the actual tank size depends on the rainfall pattern, simultaneous discharge, design return period and local regulations. Therefore, hydraulic modelling is needed to identify how much water must be held back at the critical moment.

The U.S. Environmental Protection Agency’s underground retention/detention guidance describes systems that collect runoff through inlets, store it in subsurface chambers and discharge it at controlled rates. In dense districts, underground stormwater detention can offer additional storage without dedicating a large surface site to an open pond.

Why Underground Stormwater Storage Matters in Dense Coastal Cities

Above-ground detention ponds need land. However, Manila must accommodate roads, homes, commerce, public spaces and heritage sites within an already developed urban area. Underground stormwater storage can place part of the flood-control network beneath parks, plazas, roads or parking areas, subject to structural and site constraints. As a result, the surface may continue to support its intended use after construction.

Coastal drainage presents a second challenge. For instance, elevated river levels, tides and restricted outfalls can reduce the rate at which stormwater leaves a district. Pumps and larger pipes remain important; nevertheless, they cannot always discharge at their intended capacity when receiving-water levels are high or when debris obstructs the system. In turn, temporary storage can help manage the mismatch between incoming runoff and available discharge capacity.

Manila has already invested in conventional drainage improvements. A World Bank implementation review covering November–December 2025 reported an additional 59 m³/s of pumping capacity, 10 kilometers of waterways dredged and 1,544 hectares meeting the project’s 24-hour drainage indicator. Importantly, these are documented results from the earlier reporting period, not measurements of the newly announced October 2026 RIFs. They also demonstrate why pumping, waterway maintenance and new stormwater detention facilities should be considered complementary rather than competing approaches.

Furthermore, an underground tank introduces engineering responsibilities of its own. Deep groundwater, uplift pressure, adjacent foundations, underground utilities, limited access and potentially contaminated runoff can affect feasibility. Where soil infiltration is proposed, designers must also evaluate permeability, groundwater separation and water-quality risks. In other words, underground storage saves surface space but does not remove the need for careful site investigation.

Retention vs. Detention: Understanding the Difference

The terms retention and detention are sometimes used loosely in project descriptions. Their practical difference is the intended water-management function. Detention primarily changes when runoff leaves a site; retention maintains a permanent pool, infiltrates water, or stores it for reuse, depending on the system. In practice, some facilities combine both functions.

Design questionStormwater detentionStormwater retention
Primary objectiveReduce and delay peak dischargeMaintain a permanent water pool, reduce runoff volume through infiltration or reuse, and/or support treatment
Typical arrangementDry basin, underground vault, modular detention tank or oversized pipeWet pond, infiltration facility or rainwater harvesting tank
After a stormDesigned storage drains down through a controlled outletA permanent pool may remain, or captured water may infiltrate or be reused
Critical checksOutlet capacity, peak-flow reduction, overflow and drawdown timeWater quality, permeability or reuse demand, overflow and long-term maintenance

For example, a wet retention pond can retain a permanent pool and still have an outlet for excess water. Similarly, a detention tank can incorporate infiltration or rainwater reuse if those functions are intentionally designed. The Federal Highway Administration describes this overlap in wet and dry stormwater facilities. Therefore, specifications should define storage volume, release rates and treatment objectives rather than relying on a label alone.

Beyond Manila: What October 2026 Flooding Reveals

Other October flood emergencies help explain why stormwater networks must account for both local runoff and wider watershed conditions. They do not, however, imply that an underground tank can prevent every kind of flood.

In Santiago, Chile, heavy rain and mudslides on October 8 damaged roads and homes, with at least six injuries reported. The Associated Press reported that 14.4 cm of rain had fallen in recent days in the Las Condes area, approximately nine times its average October rainfall. Consequently, such events underline the importance of planning for exceedance flows and safe overflow pathways as well as everyday drainage.

In Lucknow, India, flooding in early October was different. An Indian Express investigation traced much of the flooding to intense rainfall in the Gomti River’s upstream catchment between September 22 and 27, with floodwater arriving days later. Although local rain also contributed, high river levels and floodplain exposure were central to the event. In other words, urban detention must be coordinated with river management, floodplain planning and downstream outlet conditions.

Meanwhile, the World Meteorological Organization’s October 8 outlook warned that the strengthening El Niño could alter seasonal rainfall patterns and raise flood risks in some regions. However, a seasonal climate outlook does not establish the cause of a specific city’s flood. For infrastructure planning, the useful conclusion is to test drainage systems against local design storms and changing catchment conditions, not to assume one global weather driver explains every event.

A Practical Stormwater Management Train: From Green Roofs to Outfalls

Rather than relying on one large underground basin, planners can distribute water management across the entire catchment. Accordingly, a coordinated stormwater management train gives each intervention a specific role:

  1. Control runoff at its source. Green roofs, planted areas and other green infrastructure intercept rainfall before it reaches street drains. Depending on their design and antecedent moisture, these measures can retain some water and delay some runoff.
  2. Capture and convey water safely. Functional roof outlets, surface grades, drainage inlets, swales and pipes move runoff to appropriate treatment or storage locations. At the same time, inspection and debris removal help preserve their capacity.
  3. Remove sediment and debris before storage. For example, catch basins, sumps and other pretreatment measures reduce the material entering underground modules. This is particularly important because buried storage is harder to clean than an open basin.
  4. Temporarily detain excess runoff. Underground stormwater detention tanks hold water when inflow exceeds the discharge that downstream infrastructure can safely accommodate.
  5. Release, reuse or infiltrate under controlled conditions. Outlet structures discharge water according to the approved hydraulic design. Alternatively, suitable water can be directed to reuse or infiltration where site conditions and regulations permit. Nevertheless, emergency overflow routes remain essential.

Importantly, the arrangement must work as a system. A green roof cannot substitute for an undersized municipal outfall; likewise, a large detention tank cannot compensate for persistently blocked inlets. Instead, source control, conveyance, storage and maintenance need to support one another.

Where Modular Green Roofs and Underground Storage Fit

Modular components can support different stages of urban runoff management. However, a manufacturer’s product specification is not evidence of performance in Manila, and no cited source identifies HOENSOEY as a supplier to the city’s announced facilities. The applications below are therefore general examples for engineering-led project selection, not claims about a government contract.

Green Roof Source Control: HT-508 and HT-5020

For shallow extensive planting, the HOENSOEY HT-508 green roof module has a 500 × 500 × 80 mm tray profile. Its water-retention baskets and drainage features help configure moisture management. In addition, the manufacturer’s published specification lists recycled polypropylene (PP) as the tray material. The module can form part of a green roof stormwater management strategy, subject to roof capacity, waterproofing, planting and drainage design.

For deeper planting, the HOENSOEY HT-5020 semi-intensive green roof tray uses a 500 × 500 × 200 mm module. Nevertheless, the 200 mm dimension describes the full tray height, not the usable growing-medium depth. As a result, designers must verify the completed system’s saturated weight, substrate profile, overflow provisions and structural suitability for each roof.

Underground Detention: M2025 and M2015 Modules

For conventional buried detention tanks, the HOENSOEY M2025 stormwater attenuation module provides a nominal 1,000 × 500 × 500 mm assembled crate, with published net storage of about 0.23 m³ per module. The M2015 panel-built series offers a shared 800 × 490 mm footprint in two first-tier heights: 250 mm (M2015H) or 530 mm (M2015F). Their respective published standalone usable storage volumes are approximately 92 and 197 liters. In practice, these formats are potential components for geocellular stormwater storage, not pre-engineered solutions for any particular catchment.

Accordingly, the required module count cannot be calculated safely from nominal volume alone. Engineers must establish the tank’s usable storage under the complete layout, the target release rate, groundwater conditions, cover and traffic loads, access for maintenance, and the approved structural design. Moreover, short-term component compression ratings must not be presented as permissible long-term loads for the buried installation.

Shallow Drainage: HCR-1000 and HOENSOEY Cells

By comparison, the HCR-1000 finished module is a shallow 1,000 × 1,440 × 82 mm format built with interlocking HOENSOEY Cells. Its geometry can support shallow drainage and distributed storage applications. However, it should not be treated as interchangeable with deeper underground attenuation crates without confirming the required storage depth and tank arrangement.

For example, published HOENSOEY Cells literature gives the H5082 component an approximately 95% void ratio and certain compression-test references. These figures apply to the tested component, not to the usable storage capacity or allowable structural loading of a finished HCR installation. Therefore, geocellular stormwater modules should be selected against the entire system design, including membranes, pretreatment, pipe connections and maintenance access.

Six Checks Before Specifying Underground Stormwater Detention

For developers, architects and civil engineers, a preliminary design review should answer six questions before selecting storage modules or preparing a procurement quantity:

  1. What area actually drains into the system? Define contributing roofs, streets and landscapes, including any upstream flows that may enter during exceptional events.
  2. What storm must the design manage? Apply the local rainfall standard and assess peak inflow, total runoff and acceptable downstream discharge using appropriate hydrologic and hydraulic modelling.
  3. When can stored water leave? Check pumps, downstream pipes, receiving river levels, high tides and backflow prevention. Next, set a realistic drawdown and reset requirement between storms.
  4. What happens if design capacity is exceeded? Provide safe overflow routes and consider flooding consequences if power, pumps or outlet controls fail.
  5. What loads and site conditions will the tank face? Confirm groundwater uplift, burial depth, construction loads, long-term traffic loading and the structural behavior of the complete system.
  6. How will the facility be inspected and cleaned? Include inlet pretreatment, accessible maintenance points, sediment management and a funded inspection schedule.

In particular, these checks are important for retrofits beneath occupied urban spaces. Heritage sites such as the UST Open Field add further permitting, conservation and construction constraints. Consequently, preliminary storage targets should be treated as starting points for feasibility work rather than promises of flood elimination.

Frequently Asked Questions About Stormwater Detention

What is underground stormwater detention?

It is a system that temporarily stores runoff in buried pipes, vaults or modular chambers and releases the water through a controlled outlet. Its main purpose is to reduce and delay peak discharge into downstream drainage infrastructure.

Is Manila building a 72,000 m³ underground tank at UST?

No construction commitment for that specific proposal was reported as of October 10, 2026. Specifically, the 72,000 m³ figure concerns an earlier proposal beneath the UST Open Field. Separately, the university has an existing detention system of about 11,000 m³, and DPWH presented another campus-basin proposal for university review.

Can underground detention prevent flooding completely?

No. It can reduce flooding associated with runoff peaks within its design limits, but performance depends on inlet capacity, available storage, discharge conditions and maintenance. Major river flooding, blocked outlets, extreme rainfall or events beyond the design standard may still cause inundation.

What is the difference between stormwater detention and retention?

Detention temporarily holds runoff before controlled release, mainly to manage peak flow. Retention maintains stored water or removes some runoff through infiltration or reuse; wet ponds may also release excess water through outlets. Many real projects combine both functions.

Conclusion: Storage Is a Missing Link, Not a Standalone Cure

Manila’s October 2026 agreements show a clear direction: underground stormwater detention is becoming part of the city’s flood-management strategy because useful surface space is limited and the existing drainage network faces recurring pressure. Nevertheless, it is essential to distinguish the three agreed RIF projects from the separate, unapproved 72,000 m³ UST proposal.

Ultimately, the broader engineering lesson is practical. Effective flood resilience requires green infrastructure that slows runoff at its source, inlets that remain open, storage sized to the catchment, outlets that can discharge safely and maintenance that preserves performance year after year. Underground tanks can provide valuable breathing room during storm peaks; however, their success depends on how well they connect to everything around them.

Sources and Further Reading