A stormwater tank footprint should follow the module grid and the space around it. For a constrained underground tank, compare the M2025 and M2015 plan dimensions before fixing the excavation outline. The useful choice is the arrangement that leaves room for the complete tank, its connections and the construction sequence.

This comparison is for early layout discussions between drainage designers and project buyers. It uses current HOENSOEY product dimensions. The examples below are simple module-envelope calculations, rather than a proposed installation or a storage-capacity design.

Black M2015F panel-built rainwater module viewed from above and the front
M2015F product view from the current HOENSOEY media library. Use the dimensioned drawing to establish its footprint; perspective in a photograph is not a measuring guide.

Start with the module grid

The M2025 crate format has a published plan size of 1,000 × 500 mm. The M2015 panel-built family uses an 800 × 490 mm footprint. Its low-profile and higher-volume formats share that plan size.

These dimensions create different repeating grids. A layout drawn as a smooth rectangle can hide that difference. Therefore, draw the individual units before treating the outer rectangle as an order quantity.

Plan comparisonM2025M2015
One module envelope1,000 × 500 mm800 × 490 mm
Four long sides end to end4,000 mm3,200 mm
Four short sides across2,000 mm1,960 mm

The last two rows are arithmetic examples using nominal dimensions. They exclude perimeter components, connection details, installation tolerances and working space. They also say nothing about the water volume required by the site.

Test both directions in a narrow strip

A long strip beside a landscape area may allow several possible unit orientations. Sketch the long side along the strip first. Then turn the module envelope through 90 degrees on a second drawing. Compare the resulting rows, the unused end spaces and the positions of nearby services.

For example, four 500 mm widths make 2,000 mm, while four 490 mm widths make 1,960 mm. The 40 mm difference is a grid comparison, not a construction clearance. It would be unsafe to treat a narrow remaining gap as enough space for wrapping or installation without checking the complete detail.

Similarly, a shorter module length can change how a row finishes beside an obstruction. However, it does not automatically produce a better tank. The team still needs a connected layout, suitable pipe interfaces and an approved structural arrangement. Confirm the permitted orientation and connection pattern for the chosen family.

Black M2025 crate product view showing internal columns and open side structure
M2025 ECO Black product reference. Its column-type structure differs from the panel-built M2015 arrangement. The image is retained at its original resolution.

Draw a second boundary around the modules

The module outline is only one boundary on the plan. A second boundary should show the space required to construct and complete the tank. That space depends on the selected system and the project details.

Start at the perimeter. Identify the specified closures and wrapping arrangement, then locate pipe penetrations and transitions. Next, consider how the crew will reach the outer faces during assembly, lining and inspection. The excavation and working-space dimensions should follow the approved construction method.

An irregular corner deserves particular attention. Leaving out a unit may create room on the plan, yet change the tank boundary or the route for water movement. Do not assume that an improvised cut, a mixed connection or a combination of different module families is permitted. Obtain a revised layout showing the intended components.

This approach also makes drawings easier to compare. Each proposal should show the same surrounding constraints, rather than using a different definition of available space.

Keep the footprint separate from usable storage

A stormwater tank footprint describes an area. Required storage is a volume, and usable storage depends on the complete configuration. A larger nominal rectangle does not by itself establish how much water the installation can hold or release.

Once a workable plan has been identified, develop the vertical section with the responsible designer. Include the module arrangement, formation, surrounding layers, pipe levels and finished surface. Ask for the usable storage calculation for that arrangement. Where inspection components or other intrusions occupy space, the calculation should account for them.

Keep this review separate from structural approval too. A product compression value cannot resolve a conflict between tank levels, groundwater and the loads above. The chosen material version, layer arrangement and complete installed build-up need their own assessment.

Use the comparison to refine the enquiry

For a useful first discussion, send HOENSOEY a marked plan showing the constrained area and the nearby services. Add the required usable storage, known levels and proposed surface use. Include both candidate grids if the format remains open.

Then ask which dimensioned arrangement should be developed further. A clear comparison explains why a grid fits, where allowances remain unresolved and what evidence the project team still needs. Use the existing project enquiry page to share that information and request the relevant product drawings.