The GS-Tanks storage module is not an infinite or unrestricted storage product. In this archived article, the phrase “unlimited capacity” means that a project team can arrange modules to meet a designed volume and footprint. The final system still needs site limits, current product data, calculations, approvals, installation controls and maintenance.

The legacy passages below preserve the original manufacturer wording for continuity. However, they do not prove current material, void ratio, load, certification, water quality, service life, savings or environmental performance. Confirm every selection against the exact model and actual project.

In this guide

GS-Tanks Storage Module: Quick Specification Answer

A module is only one component. The complete system may also need excavation support, a prepared formation, structural cover, a membrane or geotextile, pretreatment, inlets, vents, access, pumps, overflow, an exceedance route and downstream controls. Therefore, a product statement cannot replace a coordinated design.

Identify the Exact GS-Tanks Storage Module

Resolve the material and void-ratio conflict

The archived copy states a 95% effective water space and mainly recycled polypropylene. A current owner-page audit states up to 96% void ratio and refers to virgin polypropylene or fully recycled polypropylene. Later on that same owner route, other module descriptions refer to HDPE or food-grade polyethylene.

Do not silently choose one material or percentage. Instead, request the current model code, revision-controlled data sheet, material declaration, dimensions, mass, void definition and batch traceability. The supplier should also identify which statement applies to the offered unit.

Freeze the proposed configuration

Record the module orientation, array dimensions, connections, inspection paths and intended surrounding layers. In addition, identify any variants, accessories or substitutions. A family name cannot show that every unit has the same geometry, resin, connection, load response or approval scope.

The project file should link the offer, drawings, data sheet, test reports and delivered batches. If the supplier changes a model or material, the responsible designers should repeat the affected hydraulic, structural, durability and construction reviews.

Define the Project Before Selecting the GS-Tanks Storage Module

Choose storage, infiltration or reuse

First, state whether the system will attenuate runoff, infiltrate water, store water for reuse or combine those functions. Each purpose changes the site investigation, water-quality controls, outlet, lining, monitoring and approval needs. Moreover, infiltration and lined storage require different evidence.

Next, define the catchments, rainfall method, runoff assumptions, inflow route and intended drawdown. Also show normal operation, blockage, saturation, pump failure and events beyond the selected design case. The authority’s current method and the lawful receiving point govern the project.

Investigate ground and groundwater

A competent site investigation should describe soil, fill, groundwater, contamination, bearing response, settlement and nearby receptors. Then the design team can assess formation preparation, flotation, infiltration, excavation, temporary works and protection of adjacent structures or utilities.

Do not assume that open storage automatically suits infiltration. Equally, do not assume that a membrane alone solves groundwater or settlement risks. The design must coordinate the module array with the ground, envelope, cover and outlet.

Read the Archived GS-Tanks Storage Module Design Copy Carefully

The following passage remains byte-exact and in its original order. Treat it as archived manufacturer copy, not a current data sheet, certification record, engineering approval or promise for a project.

GS-Tanks are developed by Leiyuan, and it is recyclable and environmentally-friendly. In addition, they are a combination of polypropylene plastic unit modules, which form an underground water storage tank. The impermeable membrane or one-way permeable geotextile is wrapped around the pool according to engineering needs. As a result, it can form a water storage tank or infiltration pool.

Modular rainwater storage tank is easy to install, has a large bearing capacity. It does not breed mosquitoes and algae. It can be dismantled and moved to other areas for continued use after being used in the temporary construction area. The equipment is suitable for rainwater collection and utilization in large building areas, industrial parks, squares and workshop areas.

Important design and installation information of GS-Tank rainwater storage module

  1. When the GS-Tank rainwater storage module is installed, the upper and lower sides with a height of 450 mm must be the pressure-bearing surface to ensure the maximum strength.
  2. The standard GS-Tank storage module is only suitable for garden areas.
  3. The enhanced GS-Tank storage module can be installed in the driving area, such as driveway and parking lot, and cover a greater depth in the driving area. Reasonable installation of the module under the road surface open to traffic must be carried out under the design requirements of professional engineers.
  4. The compressive strength of the GS-Tank storage module is tested by the authoritative certification department. The test is carried out in a controlled environment, and the soil is evenly distributed under the static load state, with the highest strength test.
  5. The safety factor of the GS-Tanks storage module should be within the compressive strength test results. This is to prevent variations due to actual conditions on site, recycled materials and any potential variable factors.

The Leiyuan rainwater module is suitable for rainwater filtration, purification, collection, recycling and other systems. This product is primarily made of recycled polypropylene. Through years of research and development, the GS-Tank rainwater module has a simple and light structure. It has 95% effective water collection space, and has a high bearing capacity. The modular design can be combined arbitrarily according to the needs of engineering design. It is widely used in rainwater utilization systems such as various construction fields, landscapes, gardens, and drainage channels.

These statements require more than a model-family name. Ask for the exact current data sheet, laboratory report, test method, temperature, load direction, support and boundary conditions, safety factor and project interpretation. In particular, the phrase “authoritative certification department” needs the document identifier, issuer, date, tested model, standard, result and scope.

The copy also combines a module with broader system outcomes. It does not establish filtration, purification, potable-water suitability, mosquito control, algae control, easy installation or reuse after dismantling. Those outcomes depend on the full design, contamination controls, access, pretreatment, operation and local requirements.

Review the Archived Characteristics Without Treating Them as Specifications

The next list preserves the original claims. It does not resolve the owner-page material and void-ratio conflicts, and it does not verify the stated load, savings, intellectual-property or water-quality language.

 Characteristics of GS-Tanks rainwater module of Leiyuan industrial CO., Ltd.

  1. High water storage rate: GS-Tank rainwater module has a water storage void ratio of 95% and a compressive strength of more than 6 tons.
  2. Easy assembly: The GS-Tank rainwater module can be quickly assembled without tools, which greatly reduces the use of construction machinery and construction intensity.
  3. Simple construction: GS-Tank rainwater module can reduce more than 30% of excavation, transportation, and 60% of backfilling.
  4. Unlimited capacity: GS-Tank rainwater module is designed as a standard module, which can be designed into various irregular shapes and sizes according to the project. Fundamentally change conventional pool settlement, cracking, leakage and many other problems.
  5. Rainwater collection: GS-Tank rainwater modules can collect rainwater from roofs, gardens, lawns, paved areas and driveways, increasing water storage and water supply capacity.
  6. Does not take up valuable space: GS-Tank rainwater modules are installed underground, and can be installed under greening, roads, squares, parking lots, and sports fields as required, without occupying ground space. In addition, it will not affect the landscape effect.
  7. Clean water storage: Rainwater is discarded and filtered before entering the rainwater GS-Tank rainwater modules. The water in the module is kept under the best conditions and there is enough space for aerobic activities. This prevents anaerobic bacteria that can affect water quality due to stagnant rainwater.
  8. Environmentally-friendly products: 100% recyclable materials, safe and pollution-free, help to improve storage water quality.
  9. Products protected by patent rights and copyright
  10. Create garden reservoirs: GS-Tanks rainwater modules can create maintenance-free reservoirs, collect rainwater continuously throughout the year, and provide a large amount of water for landscaping irrigation. Compared with traditional watering methods, it can save a lot of money every year.

Interpret “unlimited capacity” correctly

Here, “unlimited capacity” can only describe modular sizing to a designed project volume. It does not mean infinite storage, an unrestricted footprint, unlimited structural capacity or freedom from hydraulic limits. Available land, excavation, groundwater, cover, access, outlet capacity and approvals all constrain the final array.

Separate module data from system outcomes

The void and load values need model-specific test evidence and clear definitions. Likewise, the excavation and backfill percentages need a named baseline, measured quantities, system boundaries and site conditions. Do not apply any archived number to procurement or calculation until current evidence matches the exact offered unit.

A bare module does not filter or purify incoming water. It also cannot guarantee potable water, clean water, aerobic conditions, the absence of mosquitoes or algae, or improved water quality. Pretreatment, exclusion, ventilation, turnover, disinfection, monitoring and intended end use belong to the complete water-management plan.

Similarly, this record does not support “maintenance-free,” “pollution-free” or “safe” conclusions. The environmental language needs verified material composition, a defined life-cycle boundary, available recycling routes and an accepted comparison. Patent and copyright wording needs document identifiers, ownership, jurisdiction, status and scope.

Review the Archived System and Economic Claims

The following system, schedule, structural and economic statements remain as legacy manufacturer descriptions. They do not provide guaranteed outcomes, current prices, household-water advice or independently verified project results.

Leiyuan rainwater collection and comprehensive utilization system with GS-Tank modules for rainwater collection pool

  1. The GS-Tank module can quickly build various cubic rainwater storage tanks, with less excavation and backfilling workload, and can realize the same-day backfilling on the same day of excavation.
  2. Compared with concrete pools, GS-Tank has the characteristics of short construction period, convenient installation, flexible combination and longer service life.
  3. The modular structure forms a stable and unique structural space while completing the water storage, so that it has a super pressure-bearing capacity. The above pool can be used as a parking lot, green space, etc.
  4. Modules can be combined into fast drainage channels to realize drainage of squares and roads.
  5. The GS-Tank module does not require heavy hoisting and transportation equipment.
  6. In line with the ecological concept of natural construction, the stored water quality will not stink. The products are currently widely used in the rapid construction of rainwater storage tanks, infiltration drainage channels, rainwater collection along expressways and roads, rapid drainage of parking lots, water storage, etc.

Economic benefits of GS rainwater module of Leiyuan Industrial Co., Ltd.

According to the estimates of relevant experts, based on the average annual rainfall, a 40 square-meter roof can collect more than 20 cubic meters of rainwater every year, which can meet the water needs of a family of 4-5 in the dry season. 6,000 square meters of water can be circulated once a month, saving 10,000 tons of water every month, deducting the electricity bill of the water pump, and saving 20,000 yuan in water bills a month.

Soakaway Crates Rainwater Harvesting Module Infiltration Tanks

Construction time depends on excavation, formation condition, temporary works, access, weather, inspection, connections, envelope work and backfilling. Therefore, the archived schedule and plant statements cannot set a programme. Compare alternatives through drawings, quantities, sequence, risks and the same project boundary.

Parking or traffic above a tank needs project-specific structural and geotechnical design. The responsible specialists should review live loads, load direction, soil support, cover, lateral effects, creep, buoyancy, settlement, interfaces and construction loads. A phrase such as “super pressure-bearing capacity” supplies none of that evidence.

The economic paragraph lacks a named expert source, rainfall dataset, location, runoff coefficient, losses, demand profile, tariff, pump duty and treatment boundary. Consequently, it cannot predict a family’s water supply, a monthly volume or a monetary saving. Calculate yield, demand, energy, maintenance and water quality for the actual site.

Longer service life, rapid drainage and acceptable stored-water condition also need defined tests, inspection criteria and operating records. In addition, designers must provide overflow and safe exceedance routes. Storage alone does not remove the need to manage events beyond the selected design case.

Read the Archived Supplier Reasons as Sales Copy

The final source list remains visible for provenance. It describes the supplier’s position; it is not independent evidence of quality, durability, price, customization or support.

Why choose GS-Tank rainwater modules?

  1. High-Quality Products: Our stormwater and rainwater modular tanks are made from the highest quality materials and are designed to withstand harsh weather conditions. We are committed to providing products that meet the needs of our customers.
  2. Competitive Pricing: As a manufacturer, we are able to offer our products at competitive prices, without sacrificing quality. Whether you are looking to order in bulk or need a single unit, we can provide you with the best possible pricing.
  3. Customizable Solutions: We understand that every project is unique. That’s why we offer customizable solutions for our stormwater and rainwater modular tanks. We can work with you to design a solution that meets the specific needs of your project.
  4. Expert Support: Our team of experts is always available to provide support and guidance. Whether you need help with installation or have questions about our products, we are here to help.

Evaluate quality through traceable specifications, test evidence, manufacturing controls and delivered-product inspection. Meanwhile, compare price on the same scope, logistics, accessories, testing, installation, maintenance, replacement and risk allocation. Record any customization through revised drawings and renewed calculations.

Support should identify named deliverables, response routes and responsibilities. It does not transfer design approval from the responsible project professionals. Furthermore, a supplier answer does not replace authority consent, independent review or site supervision.

Build a Current GS-Tanks Storage Module Evidence Pack

Product identity and material

  • Exact model, revision, dimensions, mass, geometry, connectors and accessories.
  • Material declaration, recycled-content basis, batch traceability and manufacturing controls.
  • Current drawings and a written resolution of every owner-page specification conflict.

Structural and geotechnical evidence

  • Applicable test standard, laboratory, report identifier, specimen and date.
  • Load direction, support, boundary, temperature, duration, repetition and failure criteria.
  • Project loads, cover, soil parameters, safety factors, settlement, creep and buoyancy checks.

Hydraulic and water-quality evidence

  • Void definition, gross and usable volume, connection losses and inspection access.
  • Catchment, inflow, outlet, drawdown, overflow, blockage and exceedance calculations.
  • Pretreatment, sediment, contamination, intended reuse, monitoring and authority requirements.

Durability and environmental evidence

  • Relevant chemical, temperature, creep, joint, installation and service-condition evidence.
  • Declared service-life basis, inspection triggers, repair method and replacement assumptions.
  • Environmental boundary, comparison method, recycled-content proof and realistic end-of-life route.

No certificate title or marketing label should stand alone. The reviewer should connect every document to the exact GS-Tanks storage module, the proposed configuration and the project condition it addresses.

Coordinate the Complete GS-Tanks Storage Module System

Design the envelope and interfaces

The membrane or geotextile choice depends on the intended function and ground conditions. Therefore, specify compatible separation, filtration, protection, seams, penetrations, corners and repair methods. Also coordinate inlets, outlets, vents, inspection access and pump interfaces.

Fines migration, puncture, blocked pretreatment or an inaccessible connection can impair the system even when the modules remain intact. The design should identify each interface owner and inspection hold point before construction starts.

Plan construction and verification

Define formation acceptance, leveling, assembly, temporary restraint, protection, envelope inspection and backfill sequence. Next, record delivered batches and photograph hidden work. The team should stop on damage, contamination, unexpected ground or a product substitution.

Commission the connected system through an approved method. Check inlets, outlets, overflow, controls, pumps and access where applicable. Finally, retain as-built levels, inspection records, tests, changes and operating instructions in the handover file.

Operate, Inspect and Maintain the GS-Tanks Storage Module

A buried array is not maintenance-free. The plan should assign inspections for catchments, pretreatment, sediment, inlets, outlets, vents, access points, pumps and overflow routes. It should also define safe access, cleaning, disposal and defect escalation.

Use observations to trigger action. For example, unexpected ponding, slow drawdown, odour, sediment, pump alarms or settlement may require investigation. Do not assume that the module caused every symptom; upstream, downstream, envelope, ground and operational issues may overlap.

After a major event or site change, compare performance with the approved basis. Then update the risk assessment and maintenance plan if conditions have changed. Never use the archived “maintenance-free” phrase to omit access or monitoring.

Questions for a GS-Tanks Storage Module Review

Which GS-Tanks storage module will the project buy?

First, require a unique model code and revision. Next, match the quotation and drawings to that identity. Finally, reject an unreviewed substitution.

How Should the GS-Tanks Storage Module Define Usable Volume?

First, distinguish gross array volume from water volume. Then, include connections, access and operating limits in the calculation. Finally, document the definition that the designer used.

Which GS-Tanks Storage Module Load Case Controls the Design?

First, list every construction and operating load. Next, combine those loads with the ground, cover and groundwater conditions. Finally, ask the responsible specialists to record the governing case.

How will water enter and leave?

First, map each catchment and inlet. Then, connect pretreatment, storage, outlet, overflow and exceedance. Finally, test the route through the approved commissioning method.

What Should a GS-Tanks Storage Module Certification Show?

First, request the certificate or report identifier. Next, confirm the issuer, model, method, date, result and scope. Finally, compare that scope with the actual project use.

How will construction protect the array?

First, define formation and assembly hold points. Then, inspect the envelope and interfaces before covering them. Finally, record damage, repairs and approved changes.

Who will maintain the system?

First, assign access, inspection and cleaning duties. Next, define triggers for investigation and repair. Finally, keep the records with the as-built information.

How should the team resolve a specification conflict?

First, list the exact conflicting statements. Next, ask the supplier for a model-specific written resolution. Finally, file the evidence and the design decision together.

What does independent evidence add?

First, separate supplier declarations from laboratory reports. Next, inspect the laboratory identity, method, specimen and result. Finally, let the responsible reviewer decide whether the scope fits the project.

What Should GS-Tanks Storage Module Environmental Evidence Show?

First, define the comparison and life-cycle boundary. Next, verify material inputs, manufacturing assumptions and realistic end-of-life routes. Finally, report limitations with the conclusion.

How should the team compare alternatives?

First, freeze a common project basis. Next, compare quantities, programme, risks, operation and replacement on that basis. Finally, test how uncertain assumptions affect the choice.

What happens if part of the route blocks?

First, locate plausible blockage points. Next, assess upstream levels, overflow and safe exceedance. Finally, set inspection and response duties for each point.

What changes when a project reuses water?

First, state the intended end use. Next, identify treatment, monitoring and authority requirements. Finally, prevent unsafe connections or unsupported water-quality assumptions.

How Should the Team Control GS-Tanks Storage Module Records?

First, assign an owner for the evidence register. Next, link models, batches, drawings, reports and site inspections. Finally, retain revision history through handover and operation.

When Should GS-Tanks Storage Module Procurement Pause?

First, identify gaps that affect safety, capacity, water quality or approval. Next, assign clear closeout actions and reviewers. Finally, proceed only after the evidence resolves those gaps.

GS-Tanks Storage Module Approval Checklist

  • Define the project objective, catchments, design method, outlet and authority route.
  • Investigate soil, groundwater, contamination, settlement, flotation and nearby assets.
  • Freeze the exact model, material, revision, configuration and delivered-product traceability.
  • Resolve the owner-page material and void-ratio conflicts in writing.
  • Review current hydraulic, structural, durability and environmental evidence.
  • Connect every test to its method, conditions, model and project interpretation.
  • Design pretreatment, envelope, interfaces, access, outlet and exceedance as one system.
  • Inspect hidden work, commission the connected route and retain as-built records.
  • Assign monitoring, cleaning, repair, replacement and safe-access responsibilities.
  • Recheck the design after any substitution, site drift or operating change.

Decision rule: use the GS-Tanks storage module only when current exact-model evidence and project calculations support the selected configuration. If material, load, hydraulic, certification or water-quality evidence remains unclear, pause procurement and resolve the gap instead of relying on the archived claims.